| X-ray Diffractometer : RIGAKU |
---|
Features |
ㆍThis system can optimize all measurement and data processing parameters automatically by making a preliminary measurement. Thus, a true, fully automatic analysis mode can be selected. ㆍFully automatic computer controlled goniometer and monochromator alignement, slit exchanger, KV-mA setting are available. ㆍThe advanced software provides w completely user friendly communication with the aid of multi-windows, multi-tasking, icon, etc. using UNIX operating system. ㆍThis system will be controlled and processed by both of work station and IBM compatible. ㆍTwo wide angle goniometer system will be able to be controlled simultaneously. |

| Dilatometer: TMA801 |
---|
Features |
ㆍControl and evaluation by means of the user friendly software. ㆍCan be used in Various atmospheres. ㆍHigh resolution and accuracy |

| XRF: EX310 |
---|
Features |
ㆍSpectrometer detects elements present in the sample and determine their concentration. ㆍEnergy dispersive x-ray fluorescence spectrometer system. ㆍProvides rapid, non-destructive, multi-element determinations from the ppm to high weight percentage range for elements from sodium(Na) through uranium(U) ㆍDesigned to perform measurements across a wide range of sample matrix categories - from homogeneous, low viscosity liquids to solids, slurries, powders, pastes, and thin films. ㆍData processing system included PC based provides both DOS and Windows software. |
| MAGNETOMETER(7304) |
---|
Features |
ㆍThe model 7304, 7307 an 7312 Vibrating Sample Magnetometer(VSM) Systems combine ease-of-use with high sensitivity and measurement speed, resulting in an instrument ideally suited for production test and quality control, as well as basic and applied materials research. Measurements of moments as small as 5 x 10-8 are possible in magnetic fields ranging from 0 to 2 tesla with laboratory electromagnets. The 7304, 7307 and 7312 systems can be configured with cryostats, or high temperature oven options, thus permitting the measurement of magnetic moment from 2 k to 1000℃ (1273k) |

| HALL Effect Measurement System |
---|
Features |
ㆍMeasurement: Hall voltage, resistance, resistivity, carrier, concentration and mobility, magnetoresistance, and current voltage characteristics on four lead van der Pauw samples. ㆍMaterials: Electronic conductors, including semiconductors, metals, and superconductors. Thin films or bulk materials (single crystal or polycrystalline). Single or multiple carrier. ) |

| E-Beam Evaporator |
---|
Features |
ㆍThis equipment must be able to perform both metallic and ceramic coating works. ㆍA surface finish must be essentially the same as the substrate surface finish. ㆍThe deposition must be carried out with good thickness uniformity. ㆍAlloy coating must be produced y condensing a multi element vapor on the substrates. |

| Sputter |
---|
Specification |
ㆍProcess chamber ㆍVacuum pumping unit 1 set ㆍSubstrate rotation & heating unit 1 set ㆍSputtering gun source 3 sets ㆍVacuum gauge controller ㆍGas supply unit ㆍR.F power supply ㆍD.C power supply ㆍFrame & control box |

| Spray Dryer |
---|
Main Frame |
ㆍDryer chamber ㆍAutomizer ㆍElectric heater ㆍSlurry pump ㆍHot blast blower with damper ㆍExhaust blower with damper ㆍAir filter ㆍAtomizer rpm detector and control panel ㆍCyclone ㆍGlass jar (Powder collection or equivalent) |

| B-H ANAIZERER, Sy8232 |
---|
Features |
ㆍUltra-wide measurement frequency bandwidth ㆍDesktop size, all-in-one construction ㆍContinuous measurement function and an extensive selection of other measuring functions ㆍHigh-speed, high-precision measurement ㆍPrinter provided as standard ㆍGP-IB interface provided as standard ㆍEasy-to-view 9-inch color CRT display ㆍEasy operation with pop-up menu system ㆍEnhanced measurement efficiency with a wide range of options |

| Microload simulation system |
---|
Main Frame |
ㆍFree-standing, self-supported unit. Load capacity: Max. 200kgf ㆍMinimum load control: 0.1% of full capacity ㆍLoad resolution: 0.01% of full capacity ㆍStrain gage type load cell: High output for better resolution and precision ㆍSymmetrical output between tension & comp. Static overload capacity: 150% of rated load. ㆍUsed for measurement and/or control of force. +/-0.15% linearity ㆍAC servo motor and reducer Frame materials: Hardened steel ㆍTotal stroke: 200mm ㆍStroke resolution: 0.001mm ㆍMin. testing velocity: 0.0005mm/min ㆍMax. testing velocity: 1000mm/min ㆍUpper and lower limit S/W, Adjustable test space, Manual cross head moving function for position |

| BET Surface Area Analyzer : GEMINI 237 |
---|
Features |
ㆍAdsorption/Desorption isotherms ㆍSingle/multi point BET surface area ㆍLangmuir surface area ㆍMicropore volume/area analysis by Halsey or Harkins-Jura equation ㆍTotal pore volume ㆍBJH pore size/volume distribution ㆍFully automatic operation ㆍEasy to learn and operate with Microsoft windows version ㆍDewar elevator automatically raise and lower the LN2 bath ㆍData transfer through RS-232 port ㆍSeparate analysis/degas manifolds for preventing contamination ㆍUp to 4 analyzers can be operated simultaneously from a single computer ㆍSimultaneous degassing of six samples for adsorption analysis ㆍX-Y expansion to zoom the details ㆍOverlaid on screen from graphic of different analysis |

| Microhardeness Tester / HMV-2000AD |
---|
Features |
ㆍCabaple of testing with a low test forve and high test force. ㆍThe load duration can be set in 1-second increments between 5 and 60sec. ㆍSince a digimatic micrometer head is used in the feeding mechanism on the X-Y stage, the positional data can be digitally displayed or sent to the output port. ㆍData processing function such as hardness scale conversion and statistical calculation are provided as standard. ㆍThe result of tolerance judgment is given on the LED. |

| UTM : Instron 4411 |
---|
Features |
ㆍThis instrument should be performing tension, compression, bending, cyclic test and relaxation test by control console and PC. ㆍThis instrument is equal to or exceeds all ASTM, BS, DIN, ISO, EN, AFNOR JIS and other international standards. ㆍTwo- column structures. ㆍAutoranging for simple operation and optimum data resolution should be standard. ㆍOverload protection function should be standard. ㆍSelf identification function for load cell and extensometer should be standard. ㆍSafety interlock function should be standard. ㆍShould be setting and indicators in English, Metric and S.I units. ㆍOne -touch automatic calibration and balance for load and strain, automatic display ranging or load, extension and strain should be required. ㆍInstantaneous digital speed selection, even while a test. ㆍCycling functions for load, extension, strain should be standard. ㆍThis instrument could be attached analog X-Y recorder. ㆍShould be displayed load, extension, strain simultaneously. ㆍShould be used a position-control closed-loop servo drive system. ㆍLoad weighting accuracy is +/-0.01% of full scale or +/-0.5% of reading. ㆍStrain measuring is +/-0.05% of full scale or +/-0.5% of reading. ㆍOn-board digenetic should be standard. ㆍCertified by ISO 9001 and NAMAS. |

| Autoclave |
---|
Features |
ㆍFor chemical technology and industrial chemical processing particularly in organic, pharmaceutical, and petrochemical. ㆍConvenient Bomb support and stirrer drive system. ㆍEasy size conversion. ㆍFloor stand Model. |

| 4-Point Probe System, CMT |
---|
Main Frame |
ㆍProbe Material: Tungsten Carbide ㆍProbe distance: 1mm ㆍProbe diameter: 40μR ㆍIntensity Light Source ㆍSample Stage Dimension: up to 21 x 150 x 41mm ㆍWeight: 70g ㆍProbe pressure: 800g ㆍDust cover |

| Tube Furnace, KF-VG-1050 |
---|
Features |
ㆍAllow the degree of vacuum depending on the selection of tube and grant of pressure. ㆍThe user can uniformly adjust the zone size by selecting the controller system. |

| Diffusion Furnace |
---|
Features |
ㆍTemperature: 1500℃/Max ㆍVolt: 220v 1ph ㆍOperation Temperature: 1400℃ ㆍHeater: 1600℃/Max ㆍInsulation: 1600℃ |

| SAMPLE PREPARATION SYSTEM |
---|
Main Frame |
ㆍ2Liter, 1000rpm, Zirconia system |

| Automatic Electrolytic Thinning Machine: TENOPUL3 |
---|
Features |
ㆍPhysical adsorption ㆍChemical adsorption ㆍAllowing each sample to be tested with a different gas ㆍIn-site pretreatment of samples ㆍSelf-calibration before every test ㆍAutomatic control liquid nitrogen level |